Fire Endurance Test
 
Fire Endurance Test
Burglary Test
Certificates and Test

Safewell safes are tested and approved annually in compliance with the stringent test methods developed by international certificate organizations such as UL, JIS, SP and SK.

Safewell Safe Equipment Ltd. is the only manufacturer who has a furnace testing fire resistance and has self test ability in Hong kong. And we have certification from well known international quality institute such as UL,SP and JIS as well as KS. Because of unstable circumstances, no one free from burglary and robbery in modern society. According to sort of terrible situation, a proper counter-plan against criminals is required to SOHO and houses.


Non Impact Interior Temperatures Test (UL, JIS, SP, KS)



4 thermocouples placed inside the safe should not exceed 350°F (177°C ) for 2 hours (1 hour heating and extra 1hr cooling) during outside temp. rising up to 1,850°F (1,010°C) as shown in the graph (Non-impact interior temp)



Impact Interior Temperatures Test (UL)



The closed furnace is preheated up to 2000°F (1,093°C ) and quickly insert test sample to the preheated furnace and maintain furnace temp. for 30min at 2000°F (1,093°C ). See the graph (Impact interior temp).



Test Result



Fire-endurance test
  Newsprint and/or crumpled paper balls were readable without scorch and burnt out.
Explosion hazard test
  No explosion of the cabinet was noted as a result of the quick thermal shock.

Copyright © 2008 Safewell Equipment Limited. All rights reserved.